1204M-4201 is a controller with "24V Working Voltage" option in the "1204M/1205M Series" of CURTIS, ideal for replacing an old CURTIS 1204 controller (1204-004, 1204-036 or other 1204 controllers). With the original controller model number provided by the buyer, the seller could identify more detailed information like "voltage", "current" and "throttle type". Then the controller will be programmed to the same setting as the original one of the buyer.
As the new member of 1204M / 1205M series winding motor speed controllers, the controller model 1204M-4201 has an extra "J5" terminal which offers new function "reverse signal input" or "main contactor driver" (corresponding controller parameter "Rev Input / Main Driver").
The parameter "Rev Input / Main Driver" determines the signal input at the controller’s J5 terminal:
- 0 = reverse input and main driver both inactive; use this setting if you are replacing an earlier model with no J5 terminal and want to leave the wiring as it was.
- 1 = reverse input active (see page 7, figure 5 of controller manual).
- 2 = main driver active (see page 7, figure 4 of controller manual).

- Put the MOLEX 4-Pin connector of programmer communicating cable into the mating connector of controller 1204M-4201.
- Connect the power source positive (B+) to the controller B+ main terminal and J1 terminal.
- Connect the power source negative (B-) to the controller B- main terminal.
- switch on the DC power source, then you will see the initiating screen (handheld programmer) or you can start to connect the controller (PC Station programmer).
- Entering the programmer manual, you may choose to:
- modify the controller parameters
- monitoring the controller status
- diagnosing the controller
- viewing the error history
Relatively, programming a 1204M-4201 is relative simpler than the programming process of other CURTIS controller models. For each different controller models, CURTIS configures a different terminal setting for programmers. But there are some points are common:
- A KSI (key switch input) terminal is always available for activating the controller.
- For activating the logical circuit of a CURTIS controller, a 24V DC power (max. the rated working voltage of controller) positive (B+) should be connected to the KSI terminal.
- For some controller models, a dedicated logical enable terminal is available, should also be feed by the same B+, like KSI.
- The DC power negative (B-) should be connected to B- terminal of controller, for constructing a complete working circuit.
I am replacing a 1204-036 controller on Genie GS2030 with a 1204m-4021m. I can find no information anywhere on which type of throttle I should select. By trial and error I get some response from the platform using type 2 or type 6, but there is no response from the ground control up button with any throttle type. The up switch sends a 5volt signal to the j3 connector. There is no voltage ramp. I turned off the HPD but still no joy. Any advice ?